Tech Notes

Tech note

Selecting an f-theta lens: wavelength, focal length, scan field, spot size, telecentric

By
Shinhotek engineering
Published
2026-11-12

An f-theta lens focuses the beam onto a plane behind a galvo scanner. An ordinary lens places the focus in proportion to tan θ; an f-theta lens is designed so the position is proportional to focal length × deflection angle (f·θ), making mirror angle linear with position and scan speed constant across the field.

Wavelength sets material and coating.

WavelengthMaterialNote
355 nm UVFused silicaResists UV absorption and degradation, higher cost
532 nm green, 1,064 nm NIROptical glass or fused silicaFused silica at high power
10.6 µm CO2ZnSeLow-absorption grade, anti-reflection coating essential

Focal length sets field and spot. The field width is roughly 2 × f × maximum deflection angle. A longer focal length widens the field and the lens-to-work distance, but the focused spot grows in proportion. Decide the field from the workpiece first, then check that the resulting spot suits the process.

Input beam diameter. The lens's maximum input beam diameter must match the scanner aperture. A larger beam gives a smaller spot, but overfilling the lens clips the edges and adds diffraction and loss.

Telecentric lenses. With a standard f-theta the beam enters at an angle near the field edge, so deep holes and thick materials get tilted walls and elliptical spots. A telecentric f-theta keeps the beam perpendicular across the field, at the cost of a lens larger than the field and a higher price.

Reflections and protection. Use lenses designed so back-reflections do not return into the scanner mirrors or laser, and place a replaceable protective window in front to keep debris off the lens. A contaminated window lowers transmission and shifts the focus through thermal lensing.

Shinhotek proposes f-theta lenses for the wavelength, field and spot required, including ULO Optics lenses for CO2, together with the scanner.